Adams Rite - PS-EXIT  Power Supply - For 3000/8000 Exit Devices w/ Electric and Motorized Latch Retraction (MLR) (LR) - 24 - 28 VDC - UHS Hardware
Adams Rite - PS-LR  Power Supply - For 3000/8000 Exit Devices w/ Electric Latch Retraction (LR) - 28 VDC - UHS Hardware
Adams Rite - PS-LR  Power Supply - For 3000/8000 Exit Devices w/ Electric Latch Retraction (LR) - 28 VDC - UHS Hardware
Adams Rite - PS-LR  Power Supply - For 3000/8000 Exit Devices w/ Electric Latch Retraction (LR) - 28 VDC - UHS Hardware
Adams Rite - PS-LR  Power Supply - For 3000/8000 Exit Devices w/ Electric Latch Retraction (LR) - 28 VDC - UHS Hardware
Adams Rite - PS-EXIT  Power Supply - For 3000/8000 Exit Devices w/ Electric and Motorized Latch Retraction (MLR) (LR) - 24 - 28 VDC - UHS Hardware
Adams Rite - PS-EXIT  Power Supply - For 3000/8000 Exit Devices w/ Electric and Motorized Latch Retraction (MLR) (LR) - 24 - 28 VDC - UHS Hardware
Adams Rite - PS-EXIT  Power Supply - For 3000/8000 Exit Devices w/ Electric and Motorized Latch Retraction (MLR) (LR) - 24 - 28 VDC - UHS Hardware

Adams Rite - PS-EXIT Power Supply - For 3000/8000 Exit Devices w/ Electric and Motorized Latch Retraction (MLR) (LR) - 24 - 28 VDC

In Stock
SKU: ADR-PS-EXIT-POWERSUPPLY
NSID: 22391

Get it shipped ! Order within:

Get it shipped ! Order within:

Get an Extra Hour with

$379.90
$750.25
$379.90

LIST PRICE: $750.25

ADR-PS-EXIT-POWERSUPPLY

Linear power supply with optional battery backup for 3000 and 8000 Series vertical rod and mortise type exit devices with Motorized Latch Retraction (MLR) or Electric Latch Retraction (LR) options by delivering filtered and regulated power..

Function - This Adams Rite power supply is designed to provide power and control for up to two MLR or LR exit devices. Each exit device is controlled by a timer that is initiated by a switch closure. The timer is user-configured and holds the exit device(s) in the unlatched position for 2 – 60 seconds. At the end of the selected time, the exit device(s) will re-latch. If the switch controlling the exit device is closed longer than the selected time, the exit device remains unlatched until the controlling switch is released.

An optional mode is available that allows both retraction timers to activate in response to a closure of either switch.
Exit devices under access system control remain latched during a complete power failure but always allow free mechanical egress

More Details Below:


Call 1-800-878-6604 for Bulk / Dealer Pricing!

Features:

Certifications UL 294
CAN/CSA-C22.2 No. 223
Housing Hinged, steel cabinet measures 10" x10-3/8" x 4-1/8" [254 mm x 263.5 mm x104.8 mm]. Blue, baked enamel finish with knockouts for conduit connections. Sized to accommodate two sealed, lead acid batteries (7AH, not included).
Operating Modes The PS-EXIT is designed to power up to two 8000/3000 MLR or LR exit devices in the following operating modes:
-Single Input (Sequential Operation): either input retracts the corresponding exit device followed by retraction of second device. Control double-door exit with one input.
-Dual Input (Independent Operation): Each exit device is controlled by its own input switch. Control two separate exits with two inputs.
Input Power 115 VAC or 230 VAC, 0.7A/0.4A
Output Voltage
Up to 17 Amp @ 24 - 26 VDC